We choose the capacity by room size and window orientation. We drill the walls with a diamond drill and dust extractor, so the work stays clean both during renovation and in finished rooms.
The calculator's “from” price is for the most affordable series of each brand (Nordis Sirius, Gree Pular, Midea Solunar / Breezeless E, Samsung Cebu, Daikin Sensira). Quieter and cold-climate models cost more.
Enter the room details and see what capacity air conditioner suits it.
We calculate from the room volume: 30–40 W per cubic metre depending on the sun. We add 100 W for each person and device, then pick the nearest standard capacity. We confirm the exact capacity during the survey.
We choose the type by how many rooms need cooling and whether you want the unit to be visible.
The most common choice for a single room. The indoor unit hangs on the wall and the pipes go through the wall to the outdoor unit.
For one roomOne outdoor unit serves 2–5 indoor units. Good for an apartment with room on the facade for only one unit.
For 2–5 roomsThe unit is hidden in a suspended ceiling and ducts distribute the air to several rooms. Only the grilles are visible.
Hidden in the ceilingFitted into a suspended ceiling, it blows air in four directions. Usually suits offices and commercial premises.
For offices and hallsWe work to refrigeration standards: we vacuum every pipe run and test it for leaks.
Insulated copper pipes, power and control cables, corrugated condensate hose.
We drill one opening through an outer wall up to 50 cm thick. An industrial vacuum extracts the dust, and the facade finish stays intact.
We hang the outdoor unit on anti-vibration brackets with rubber dampers, so the wall does not vibrate or hum.
We install one wall-mounted air conditioner in about 4 hours.
We assess the room, the window orientation and where to hang both units. We choose the capacity.
We drill the opening and run the refrigerant pipes, cables and condensate hose.
We level the indoor unit and fix the outdoor unit on anti-vibration brackets.
A vacuum pump removes air and moisture from the pipes, we test for leaks and show you how to use it.
In heating mode an air conditioner works as an air-to-air heat pump: it takes heat from the outdoor air and moves it into the room. From 1 kWh of electricity it produces 3–5 kWh of heat, while an electric radiator gives only 1 kWh.
Efficiency drops in the cold, so for heating we recommend cold-climate models such as Gree Amber Nordic, which heats even at −30 °C.
An air conditioner does not bring fresh air into the room: it only cools or heats the air already there. For the air to change around the clock, you need a heat recovery ventilation system.
Yes. We usually hang the outdoor unit on a balcony, a loggia or the facade. For the facade, it is worth checking with the residents' association or building manager in advance.
Yes. Cold-climate models heat even at −25 °C, and heating with them costs less than with an electric radiator.
The quietest indoor units run from 16 dB, quieter than a whisper. We mount the outdoor unit on brackets with dampers so vibration does not carry sound into the wall.
Yes. During renovation we hide the refrigerant pipes in the wall or ceiling and hang the units after painting. In finished rooms we run the pipes in decorative trunking.
In summer, wash the indoor unit filters with warm water every 2–4 weeks. Once a year it is worth booking a service: we clean and disinfect the unit and check the refrigerant pressure.
A wall-mounted air conditioner with standard installation costs from €569. The price by room size and brand is shown by the calculator on the home page. We give the exact price after the survey: it depends on the pipe run length, the wall and the unit capacity.
We will come, measure the room and offer a model with a price. We reply to enquiries on the same working day.