A heat recovery unit replaces the air in your home around the clock and returns most of the heat from the extracted air. Here you will find how the types differ, what airflow your house needs and what the units of the manufacturers we work with cost.
The heat recovery unit is the heart of a mechanical ventilation system. It has two fans: one extracts air from the bathroom, kitchen and walk-in wardrobe, the other supplies outdoor air to the bedrooms and living room. Both airflows pass through a heat exchanger, so in winter the supply air is warmed by the extracted air and the house does not cool down.
A well-chosen unit returns 85–96% of the heat and uses 30–60 W of electricity in normal mode. Filters stop dust and pollen, and in summer the bypass damper lets cooler night air in past the heat exchanger.
How the system is installed in a house and how long the work takes is described on the heat recovery installation page.
The main difference is the heat exchanger. It decides whether the unit needs a condensate drain, whether it returns moisture and how it copes with frost.
Heat is carried by a rotating aluminium wheel. It does not freeze in hard frost, needs no condensate drain, and part of the moisture returns to the rooms.
The airflows run through thin channels side by side and never mix. The unit is quiet and efficient, but condensate forms in the extracted air, so it needs a drain and frost protection.
A polymer membrane transfers not only heat but also moisture. In the heating season the indoor air does not dry out, and odours do not return to the rooms.
Mounted in the wall for a single room, no ducts needed. It suits places where a central system cannot be installed, but it ventilates only the room it is fitted in.
The airflow is calculated from the room volume: in a home all the air should be replaced roughly every two hours. We choose a unit with a margin, so that in normal mode it runs at no more than 70% of its capacity. Then it is quiet and the fans last longer.
| House area | Required airflow | Unit capacity at least |
|---|---|---|
| 80 m² | ~110 m³/h | 150 m³/h |
| 100 m² | ~135 m³/h | 200 m³/h |
| 120 m² | ~160 m³/h | 230 m³/h |
| 150 m² | ~200 m³/h | 290 m³/h |
| 200 m² | ~270 m³/h | 390 m³/h |
| 250 m² | ~340 m³/h | 480 m³/h |
Ceiling height 2.7 m. We calculate the exact airflow for each room according to its use, so the table is a guide only.
The price of the unit and installation for your floor area is shown by the quote calculator.
Manufacturers' spec sheets are full of numbers. These matter most in daily use.
Look at the efficiency at the airflow your house will need, not at the maximum or minimum.
EC fans use less electricity. In normal mode a house unit needs 30–60 W.
Important if the unit will hang close to the bedrooms. With silencers in the main ducts, the supply air in a bedroom is quieter than 24 dB.
An F7 (ePM1) filter on the supply air stops most pollen and fine dust. Check the price of replacement filters too.
If there is no utility room, choose a ceiling-mounted unit. Slimmer models fit into a suspended ceiling; on one of our projects it was 299 mm high.
Humidity and CO₂ sensors raise the airflow automatically when someone showers or guests arrive.
We install Recom, Zehnder, Brink, Flexit and Ensy units. We choose the unit by airflow, available space and budget, not by one favourite brand.
| Manufacturer | Heat exchanger | Ceiling-mounted models |
|---|---|---|
| Recom | Rotary and enthalpy plate | Yes |
| Zehnder | Plate and enthalpy | Yes |
| Brink | Plate and enthalpy | Yes |
| Flexit | Rotary | Yes |
| Ensy | Rotary | Yes |
What each manufacturer's unit and the whole system with installation cost, you will find on the heat recovery prices page.
Usually in a utility room, boiler room, storeroom or attic. There must be room around the unit to change filters, and for a plate unit a way to drain condensate into the sewer. We hang the unit as far from the bedrooms as possible.
When there is no spare room, we hide a ceiling-mounted unit in the suspended ceiling of a corridor or storeroom and leave a hatch for servicing.
There is no single best one. A rotary unit is reliable in frost and needs no drain; an enthalpy unit keeps moisture and fully separates the airflows. We choose by floor area, space for the unit and whether the house gets too dry in winter.
Yes. In a flat there is usually room for the unit in a storeroom or the suspended ceiling of the corridor, and we hide the ducts in the ceiling. Heat recovery for a flat or a small house up to 100 m² costs from €1,790.
30–60 W in normal mode. That is about 22–43 kWh a month, similar to 3–6 LED bulbs left on around the clock.
Every 3–6 months, more often near a busy road or construction site. Once a year it is worth booking a technical check-up. More on the heat recovery maintenance page.
No. It replaces the air and saves heat, but it does not cool the rooms on a hot day. If the house is too hot in summer, you need an air conditioner.
Send us the house plan: we will calculate the airflow for each room and suggest suitable units with prices.